Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 221
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38609733

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society (HRS), the Asia Pacific HRS, and the Latin American HRS.

4.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38587017

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , América Latina , Resultado do Tratamento , Catéteres , Ásia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
5.
J Am Heart Assoc ; 13(3): e031489, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38240222

RESUMO

BACKGROUND: Embolic stroke of unknown source (ESUS) accounts for 1 in 6 ischemic strokes. Current guidelines do not recommend routine cardiac magnetic resonance (CMR) imaging in ESUS, and beyond the identification of cardioembolic sources, there are no data assessing new clinical findings from CMR in ESUS. This study aimed to assess the prevalence of new cardiac and noncardiac findings and to determine their impact on clinical care in patients with ESUS. METHODS AND RESULTS: In this prospective, multicenter, observational study, CMR imaging was performed within 3 months of ESUS. All scans were reported according to standard clinical practice. A new clinical finding was defined as one not previously identified through prior clinical evaluation. A clinically significant finding was defined as one resulting in further investigation, follow-up, or treatment. A change in patient care was defined as initiation of medical, interventional, surgical, or palliative care. From 102 patients recruited, 96 underwent CMR imaging. One or more new clinical findings were observed in 59 patients (61%). New findings were clinically significant in 48 (81%) of these patients. Of 40 patients with a new clinically significant cardiac finding, 21 (53%) experienced a change in care (medical therapy, n=15; interventional/surgical procedure, n=6). In 12 patients with a new clinically significant extracardiac finding, 6 (50%) experienced a change in care (medical therapy, n=4; palliative care, n=2). CONCLUSIONS: CMR imaging identifies new clinically significant cardiac and noncardiac findings in half of patients with recent ESUS. Advanced cardiovascular screening should be considered in patients with ESUS. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04555538.


Assuntos
AVC Embólico , Embolia Intracraniana , Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/epidemiologia , Prevalência , Estudos Prospectivos , Imageamento por Ressonância Magnética , Embolia Intracraniana/diagnóstico por imagem , Embolia Intracraniana/epidemiologia , Fatores de Risco
6.
BMJ Support Palliat Care ; 13(e3): e597-e611, 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-37098444

RESUMO

BACKGROUND: Poor psychological well-being among healthcare staff has implications for staff sickness and absence rates, and impacts on the quality, cost and safety of patient care. Although numerous studies have explored the well-being of hospice staff, study findings vary and the evidence has not yet been reviewed and synthesised. Using job demands-resources (JD-R) theory, this review aimed to investigate what factors are associated with the well-being of hospice staff. METHODS: We searched MEDLINE, CINAHL and PsycINFO for peer-reviewed quantitative, qualitative or mixed-methods studies focused on understanding what contributes to the well-being of hospice staff who provide care to patients (adults and children). The date of the last search was 11 March 2022. Studies were published from 2000 onwards in the English language and conducted in Organisation for Economic Co-operation and Development countries. Study quality was assessed using the Mixed Methods Appraisal Tool. Data synthesis was conducted using a result-based convergent design, which involved an iterative, thematic approach of collating data into distinct factors and mapping these to the JD-R theory. RESULTS: A total of 4016 unique records were screened by title and abstract, 115 full-text articles were retrieved and reviewed and 27 articles describing 23 studies were included in the review. The majority of the evidence came from studies of staff working with adult patients. Twenty-seven individual factors were identified in the included studies. There is a strong and moderate evidence that 21 of the 27 identified factors can influence hospice staff well-being. These 21 factors can be grouped into three categories: (1) those that are specific to the hospice environment and role, such as the complexity and diversity of the hospice role; (2) those that have been found to be associated with well-being in other similar settings, such as relationships with patients and their families; and (3) those that affect workers regardless of their role and work environment, that is, that are not unique to working in a healthcare role, such as workload and working relationships. There was strong evidence that neither staff demographic characteristics nor education level can influence well-being. DISCUSSION: The factors identified in this review highlight the importance of assessing both positive and negative domains of experience to determine coping interventions. Hospice organisations should aim to offer a wide range of interventions to ensure their staff have access to something that works for them. These should involve continuing or commencing initiatives to protect the factors that make hospices good environments in which to work, as well as recognising that hospice staff are also subject to many of the same factors that affect psychological well-being in all work environments. Only two studies included in the review were set in children's hospices, suggesting that more research is needed in these settings. PROSPERO REGISTRATION NUMBER: CRD42019136721 (Deviations from the protocol are noted in Table 8, Supplementary material).


Assuntos
Pessoal Técnico de Saúde , Cuidados Paliativos na Terminalidade da Vida , Hospitais para Doentes Terminais , Humanos , Bem-Estar Psicológico , Pesquisa Qualitativa , Pessoal Técnico de Saúde/psicologia
7.
Arch Dis Child ; 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-38129118

RESUMO

OBJECTIVE: To assess the risks, benefits and resource implications of using home-blended food in children with gastrostomy tubes compared with currently recommended formula feeds. DESIGN: This is a cohort study. Data were collected at months 0, 12 and 18 from parents and clinicians using standardised measures. SETTING: 32 sites across England: 28 National Health Service trusts and 4 children's hospices. PATIENTS: Children aged 6 months-18 years who were gastrostomy fed. MAIN OUTCOME MEASURE: The main outcome measure was the PedsQL Gastrointestinal Symptoms Scales score. Secondary outcomes included quality of life, sleep (child, parent), dietary intake, anthropometry, healthcare usage, safety outcomes and resource use. RESULTS: 180 children and families completed the baseline data collection, with 134 (74%) and 105 (58%) providing follow-up data at 12 and 18 months. There were fewer gastrointestinal (GI) symptoms at all time points in the home-blended diet group, but there was no difference in change over time within or between the groups. The nutritional intake of those on a home-blended diet had higher calories per kilogram and fibre, and both home-blended and formula-fed children have values above the dietary reference values for most micronutrients. Safety outcomes were similar between groups and over time. The total costs to the statutory sector were higher among children who were formula fed, but the costs of purchasing special equipment for home-blended food and the total time spent on childcare were higher for families with home-blended diet. CONCLUSIONS: Children who are gastrostomy fed a home-blended diet have similar safety profile, adequate nutritional intake and lower burden of GI symptoms than formula-fed children.Trial registration number ISRCTN13977361.

8.
Dev Med Child Neurol ; 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37946550

RESUMO

AIM: To assess the risks, benefits, and resource implications of home-blended food for children with gastrostomy tubes compared with a formula diet. METHOD: This prospective cohort study of children (aged 0-18 years) collected baseline data on gastrointestinal symptoms, nutritional intake, anthropometric outcomes, parent and child quality of life, and resource use. A propensity score-weighted generalized linear mixed model was used to compare children receiving a home-blended versus formula diet. RESULTS: Baseline data were obtained for 180 children (2019-2021; 107 males, 73 females; mean age 9 years 7 months [SD 4 years 5 months]). Children receiving a home-blended diet (n = 104) had similar diagnoses and age but more lived in areas of lower deprivation and parental education was higher compared to the parents of children receiving a formula diet (n = 76). Children receiving home-blended diets had significantly better gastrointestinal scores than those receiving formula diets (B = 13.8, p < 0.001). The number of gut infections and tube blockages were similar between the two groups but with fewer stoma site infections in the group receiving home-blended food. Children receiving a home-blended diet had more fibre in their diet compared to children receiving a formula diet. INTERPRETATION: Home-blended diets should be seen as a safe option for children who are gastrostomy-fed unless clinically contraindicated. Equality of access to home-blended diets for children with gastrostomy should be assessed by local clinical teams.

9.
Heart Rhythm O2 ; 4(11): 700-707, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38034887

RESUMO

Background: There are conflicting data on whether new-onset atrial fibrillation (AF) is independently associated with poor outcomes in COVID-19 patients. This study represents the largest dataset curated by manual chart review comparing clinical outcomes between patients with sinus rhythm, pre-existing AF, and new-onset AF. Objective: The primary aim of this study was to assess patient outcomes in COVID-19 patients with sinus rhythm, pre-existing AF, and new-onset AF. The secondary aim was to evaluate predictors of new-onset AF in patients with COVID-19 infection. Methods: This was a single-center retrospective study of patients with a confirmed diagnosis of COVID-19 admitted between March and September 2020. Patient demographic data, medical history, and clinical outcome data were manually collected. Adjusted comparisons were performed following propensity score matching between those with pre-existing or new-onset AF and those without AF. Results: The study population comprised of 1241 patients. A total of 94 (7.6%) patients had pre-existing AF and 42 (3.4%) patients developed new-onset AF. New-onset AF was associated with increased in-hospital mortality before (odds ratio [OR] 3.58, 95% confidence interval [CI] 1.78-7.06, P < .005) and after (OR 2.80, 95% CI 1.01-7.77, P < .005) propensity score matching compared with the no-AF group. However, pre-existing AF was not independently associated with in-hospital mortality compared with patients with no AF (postmatching OR: 1.13, 95% CI 0.57-2.21, P = .732). Conclusion: New-onset AF, but not pre-existing AF, was independently associated with elevated mortality in patients hospitalised with COVID-19. This observation highlights the need for careful monitoring of COVID-19 patients with new-onset AF. Further research is needed to explain the mechanistic relationship between new-onset AF and clinical outcomes in COVID-19 patients.

10.
Comput Biol Med ; 162: 107009, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37301099

RESUMO

This work presents an open-source software pipeline to create patient-specific left atrial models with fibre orientations and a fibrDEFAULTosis map, suitable for electrophysiology simulations, and quantifies the intra and inter observer reproducibility of the model creation. The semi-automatic pipeline takes as input a contrast enhanced magnetic resonance angiogram, and a late gadolinium enhanced (LGE) contrast magnetic resonance (CMR). Five operators were allocated 20 cases each from a set of 50 CMR datasets to create a total of 100 models to evaluate inter and intra-operator variability. Each output model consisted of: (1) a labelled surface mesh open at the pulmonary veins and mitral valve, (2) fibre orientations mapped from a diffusion tensor MRI (DTMRI) human atlas, (3) fibrosis map extracted from the LGE-CMR scan, and (4) simulation of local activation time (LAT) and phase singularity (PS) mapping. Reproducibility in our pipeline was evaluated by comparing agreement in shape of the output meshes, fibrosis distribution in the left atrial body, and fibre orientations. Reproducibility in simulations outputs was evaluated in the LAT maps by comparing the total activation times, and the mean conduction velocity (CV). PS maps were compared with the structural similarity index measure (SSIM). The users processed in total 60 cases for inter and 40 cases for intra-operator variability. Our workflow allows a single model to be created in 16.72 ± 12.25 min. Similarity was measured with shape, percentage of fibres oriented in the same direction, and intra-class correlation coefficient (ICC) for the fibrosis calculation. Shape differed noticeably only with users' selection of the mitral valve and the length of the pulmonary veins from the ostia to the distal end; fibrosis agreement was high, with ICC of 0.909 (inter) and 0.999 (intra); fibre orientation agreement was high with 60.63% (inter) and 71.77% (intra). The LAT showed good agreement, where the median ± IQR of the absolute difference of the total activation times was 2.02 ± 2.45 ms for inter, and 1.37 ± 2.45 ms for intra. Also, the average ± sd of the mean CV difference was -0.00404 ± 0.0155 m/s for inter, and 0.0021 ± 0.0115 m/s for intra. Finally, the PS maps showed a moderately good agreement in SSIM for inter and intra, where the mean ± sd SSIM for inter and intra were 0.648 ± 0.21 and 0.608 ± 0.15, respectively. Although we found notable differences in the models, as a consequence of user input, our tests show that the uncertainty caused by both inter and intra-operator variability is comparable with uncertainty due to estimated fibres, and image resolution accuracy of segmentation tools.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/diagnóstico por imagem , Reprodutibilidade dos Testes , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Imageamento por Ressonância Magnética/métodos , Fibrose , Valor Preditivo dos Testes
11.
J Clin Med ; 12(9)2023 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-37176490

RESUMO

There is increasing evidence to suggest that atrial fibrillation is associated with a heightened risk of dementia. The mechanism of interaction is unclear. Atrial fibrillation-induced cerebral infarcts, hypoperfusion, systemic inflammation, and anticoagulant therapy-induced cerebral microbleeds, have been proposed to explain the link between these conditions. An understanding of the pathogenesis of atrial fibrillation-associated cognitive decline may enable the development of treatment strategies targeted towards the prevention of dementia in atrial fibrillation patients. The aim of this review is to explore the impact that existing atrial fibrillation treatment strategies may have on cognition and the putative mechanisms linking the two conditions. This review examines how components of the 'Atrial Fibrillation Better Care pathway' (stroke risk reduction, rhythm control, rate control, and risk factor management) may influence the trajectory of atrial fibrillation-associated cognitive decline. The requirements for further prospective studies to understand the mechanistic link between atrial fibrillation and dementia and to develop treatment strategies targeted towards the prevention of atrial fibrillation-associated cognitive decline, are highlighted.

12.
Comput Biol Med ; 153: 106528, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36634600

RESUMO

BACKGROUND: Personalised computer models are increasingly used to diagnose cardiac arrhythmias and tailor treatment. Patient-specific models of the left atrium are often derived from pre-procedural imaging of anatomy and fibrosis. These images contain noise that can affect simulation predictions. There are few computationally tractable methods for propagating uncertainties from images to clinical predictions. METHOD: We describe the left atrium anatomy using our Bayesian shape model that captures anatomical uncertainty in medical images and has been validated on 63 independent clinical images. This algorithm describes the left atrium anatomy using Nmodes=15 principal components, capturing 95% of the shape variance and calculated from 70 clinical cardiac magnetic resonance (CMR) images. Latent variables encode shape uncertainty: we evaluate their posterior distribution for each new anatomy. We assume a normally distributed prior. We use the unscented transform to sample from the posterior shape distribution. For each sample, we assign the local material properties of the tissue using the projection of late gadolinium enhancement CMR (LGE-CMR) onto the anatomy to estimate local fibrosis. To test which activation patterns an atrium can sustain, we perform an arrhythmia simulation for each sample. We consider 34 possible outcomes (31 macro-re-entries, functional re-entry, atrial fibrillation, and non-sustained arrhythmia). For each sample, we determine the outcome by comparing pre- and post-ablation activation patterns following a cross-field stimulus. RESULTS: We create patient-specific atrial electrophysiology models of ten patients. We validate the mean and standard deviation maps from the unscented transform with the same statistics obtained with 12,000 Monte Carlo (ground truth) samples. We found discrepancies <3% and <2% for the mean and standard deviation for fibrosis burden and activation time, respectively. For each patient case, we then compare the predicted outcome from a model built on the clinical data (deterministic approach) with the probability distribution obtained from the simulated samples. We found that the deterministic approach did not predict the most likely outcome in 80% of the cases. Finally, we estimate the influence of each source of uncertainty independently. Fixing the anatomy to the posterior mean and maintaining uncertainty in fibrosis reduced the prediction of self-terminating arrhythmias from ≃14% to ≃7%. Keeping the fibrosis fixed to the sample mean while retaining uncertainty in shape decreased the prediction of substrate-driven arrhythmias from ≃33% to ≃18% and increased the prediction of macro-re-entries from ≃54% to ≃68%. CONCLUSIONS: We presented a novel method for propagating shape uncertainty in atrial models through to uncertainty in numerical simulations. The algorithm takes advantage of the unscented transform to compute the output distribution of the outcomes. We validated the unscented transform as a viable sampling strategy to deal with anatomy uncertainty. We then showed that the prediction computed with a deterministic model does not always coincide with the most likely outcome. Finally, we found that shape uncertainty affects the predictions of macro-re-entries, while fibrosis uncertainty affects the predictions of functional re-entries.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Meios de Contraste , Incerteza , Teorema de Bayes , Gadolínio , Átrios do Coração , Imageamento por Ressonância Magnética/métodos , Fibrose
13.
Europace ; 25(2): 469-477, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36369980

RESUMO

AIMS: Existing strategies that identify post-infarct ventricular tachycardia (VT) ablation target either employ invasive electrophysiological (EP) mapping or non-invasive modalities utilizing the electrocardiogram (ECG). Their success relies on localizing sites critical to the maintenance of the clinical arrhythmia, not always recorded on the 12-lead ECG. Targeting the clinical VT by utilizing electrograms (EGM) recordings stored in implanted devices may aid ablation planning, enhancing safety and speed and potentially reducing the need of VT induction. In this context, we aim to develop a non-invasive computational-deep learning (DL) platform to localize VT exit sites from surface ECGs and implanted device intracardiac EGMs. METHODS AND RESULTS: A library of ECGs and EGMs from simulated paced beats and representative post-infarct VTs was generated across five torso models. Traces were used to train DL algorithms to localize VT sites of earliest systolic activation; first tested on simulated data and then on a clinically induced VT to show applicability of our platform in clinical settings. Localization performance was estimated via localization errors (LEs) against known VT exit sites from simulations or clinical ablation targets. Surface ECGs successfully localized post-infarct VTs from simulated data with mean LE = 9.61 ± 2.61 mm across torsos. VT localization was successfully achieved from implanted device intracardiac EGMs with mean LE = 13.10 ± 2.36 mm. Finally, the clinically induced VT localization was in agreement with the clinical ablation volume. CONCLUSION: The proposed framework may be utilized for direct localization of post-infarct VTs from surface ECGs and/or implanted device EGMs, or in conjunction with efficient, patient-specific modelling, enhancing safety and speed of ablation planning.


Assuntos
Ablação por Cateter , Aprendizado Profundo , Taquicardia Ventricular , Humanos , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Eletrocardiografia/métodos , Infarto/cirurgia
14.
Front Cardiovasc Med ; 9: 989886, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36186961

RESUMO

Cardiac stereotactic body radiation therapy (cSBRT) is a non-invasive treatment modality that has been recently reported as an effective treatment for ventricular arrhythmias refractory to medical therapy and catheter ablation. The approach leverages tools developed and refined in radiation oncology, where experience has been accumulated in the treatment of a wide variety of malignant conditions. However, important differences exist between rapidly dividing malignant tumor cells and fully differentiated myocytes in pathologically remodeled ventricular myocardium, which represent the respective radiation targets. Despite its initial success, little is known about the radiobiology of the anti-arrhythmic effect cSBRT. Pre-clinical data indicates a late fibrotic effect of that appears between 3 and 4 months following cSBRT, which may result in conduction slowing and block. However, there is clear clinical evidence of an anti-arrhythmic effect of cSBRT that precedes the appearance of radiation induced fibrosis for which the mechanism is unclear. In addition, the data to date suggests that even the late anti-arrhythmic effect of cSBRT is not fully attributable to radiation.-induced fibrosis. Pre-clinical data has identified upregulation of proteins expected to result in both increased cell-to-cell coupling and excitability in the early post cSBRT period and demonstrated an associated increase in myocardial conduction velocity. These observations indicate a complex response to radiotherapy and highlight the lack of clarity regarding the different stages of the anti-arrhythmic mechanism of cSBRT. It may be speculated that in the future cSBRT therapy could be planned to deliver both early and late radiation effects titrated to optimize the combined anti-arrhythmic efficacy of the treatment. In addition to these outstanding mechanistic questions, the optimal patient selection, radiation modality, radiation dose and treatment planning strategy are currently being investigated. In this review, we consider the structural and functional effect of radiation on myocardium and the possible anti-arrhythmic mechanisms of cSBRT. Review of the published data highlights the exciting prospects for the development of knowledge and understanding in this area in which so many outstanding questions exist.

15.
Front Cardiovasc Med ; 9: 971869, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36093156

RESUMO

Cardiac MR thermometry shows promise for real-time guidance of radiofrequency ablation of cardiac arrhythmias. This technique uses ECG triggering, which can be unreliable in this situation. A prospective cardiac triggering method was developed for MR thermometry using the active tracking (AT) signal measured from catheter microcoils. In the proposed AT-based cardiac triggering (AT-trig) sequence, AT modules were repeatedly acquired to measure the catheter motion until a cardiac trigger was identified to start cardiac MR thermometry using single-shot echo-planar imaging. The AT signal was bandpass filtered to extract the motion induced by the beating heart, and cardiac triggers were defined as the extremum (peak or valley) of the filtered AT signal. AT-trig was evaluated in a beating heart phantom and in vivo in the left ventricle of a swine during temperature stability experiments (6 locations) and during one ablation. Stability was defined as the standard deviation over time. In the phantom, AT-trig enabled triggering of MR thermometry and resulted in higher temperature stability than an untriggered sequence. In all in vivo experiments, AT-trig intervals matched ECG-derived RR intervals. Mis-triggers were observed in 1/12 AT-trig stability experiments. Comparable stability of MR thermometry was achieved using peak AT-trig (1.0 ± 0.4°C), valley AT-trig (1.1 ± 0.5°C), and ECG triggering (0.9 ± 0.4°C). These experiments show that continuously acquired AT signal for prospective cardiac triggering is feasible. MR thermometry with AT-trig leads to comparable temperature stability as with conventional ECG triggering. AT-trig could serve as an alternative cardiac triggering strategy in situations where ECG triggering is not effective.

16.
Med Image Anal ; 80: 102483, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35667328

RESUMO

Catheter ablation is currently the only curative treatment for scar-related ventricular tachycardias (VTs). However, not only are ablation procedures long, with relatively high risk, but success rates are punitively low, with frequent VT recurrence. Personalized in-silico approaches have the opportunity to address these limitations. However, state-of-the-art reaction diffusion (R-D) simulations of VT induction and subsequent circuits used for in-silico ablation target identification require long execution times, along with vast computational resources, which are incompatible with the clinical workflow. Here, we present the Virtual Induction and Treatment of Arrhythmias (VITA), a novel, rapid and fully automated computational approach that uses reaction-Eikonal methodology to induce VT and identify subsequent ablation targets. The rationale for VITA is based on finding isosurfaces associated with an activation wavefront that splits in the ventricles due to the presence of an isolated isthmus of conduction within the scar; once identified, each isthmus may be assessed for their vulnerability to sustain a reentrant circuit, and the corresponding exit site automatically identified for potential ablation targeting. VITA was tested on a virtual cohort of 7 post-infarcted porcine hearts and the results compared to R-D simulations. Using only a standard desktop machine, VITA could detect all scar-related VTs, simulating activation time maps and ECGs (for clinical comparison) as well as computing ablation targets in 48 minutes. The comparable VTs probed by the R-D simulations took 68.5 hours on 256 cores of high-performance computing infrastructure. The set of lesions computed by VITA was shown to render the ventricular model VT-free. VITA could be used in near real-time as a complementary modality aiding in clinical decision-making in the treatment of post-infarction VTs.


Assuntos
Ablação por Cateter , Infarto do Miocárdio , Taquicardia Ventricular , Animais , Arritmias Cardíacas/cirurgia , Cicatriz , Eletrocardiografia , Humanos , Suínos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia
17.
J Interv Card Electrophysiol ; 65(1): 227-237, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35737208

RESUMO

BACKGROUND: Atrial fibrillation (AF) is associated with atrial septal defects (ASDs), but the mechanism of arrhythmia in these patients is poorly understood. We hypothesised that right-sided atrial ectopy may predominate in this cohort. Here, we aimed to localise the origin of spontaneous and provoked atrial ectopy in ASD patients. METHODS: Following invasive calibration of P-wave axes, 24-h Holter monitoring was used to determine the chamber of origin of spontaneous atrial ectopy. Simultaneous electrogram recording from multiple intra-cardiac catheters was used to determine the chamber of origin of isoprenaline-provoked ectopy. Comparison was made to a group of non-congenital heart disease AF patients. RESULTS: Amongst ASD patients, a right-sided origin for spontaneous atrial ectopy was significantly more prevalent than a left-sided origin (24/30 patients with right-sided ectopy vs. 14/30 with left-sided ectopy, P = 0.015). Amongst AF patients, there was no difference in the prevalence of spontaneous right vs. left-sided ectopy. For isoprenaline-provoked ectopy, there was no significant difference in the proportions of patients with right-sided or left-sided ectopy in either group. CONCLUSIONS: When spontaneous atrial ectopy occurs in ASD patients, it is significantly more prevalent from a right-sided than left-sided origin. Isoprenaline infusion did not reveal the predilection for right-sided ectopy during electrophysiology study.


Assuntos
Fibrilação Atrial , Comunicação Interatrial , Estudos de Coortes , Eletrocardiografia Ambulatorial , Comunicação Interatrial/complicações , Comunicação Interatrial/diagnóstico por imagem , Humanos , Isoproterenol
18.
Heart Rhythm O2 ; 3(2): 186-195, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35496454

RESUMO

Background: The effect of chronic ischemic scar on repolarization is unclear, with conflicting results from human and animal studies. An improved understanding of electrical remodeling within scar and border zone tissue may enhance substrate-guided ablation techniques for treatment of ventricular tachycardia. Computational modeling studies have suggested increased dispersion of repolarization during epicardial, but not endocardial, left ventricular pacing, in close proximity to scar. However, the effect of endocardial pacing near scar in vivo is unknown. Objective: The purpose of this study was to investigate the effect of scar and pacing location on local repolarization in a porcine myocardial infarction model. Methods: Six model pigs underwent late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) imaging followed by electroanatomic mapping of the left ventricular endocardium. LGE-CMR images were registered to the anatomic shell and scar defined by LGE. Activation recovery intervals (ARIs), a surrogate for action potential duration, and local ARI gradients were calculated from unipolar electrograms within areas of late gadolinium enhancement (aLGE) and healthy myocardium. Results: There was no significant difference between aLGE and healthy myocardium in mean ARI (304.20 ± 19.44 ms vs 300.59 ± 19.22 ms; P = .43), ARI heterogeneity (23.32 ± 11.43 ms vs 24.85 ± 12.99 ms; P = .54), or ARI gradients (6.18 ± 2.09 vs 5.66 ± 2.32 ms/mm; P = .39). Endocardial pacing distance from scar did not affect ARI gradients. Conclusion: Our findings suggest that changes in ARI are not an intrinsic property of surviving myocytes within scar, and endocardial pacing close to scar does not affect local repolarization.

19.
Heart Rhythm O2 ; 3(2): 196-203, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35496458

RESUMO

Background: Initiation of anticoagulation therapy in ischemic stroke patients is contingent on a clinical diagnosis of atrial fibrillation (AF). Results from previous studies suggest thromboembolic risk may predate clinical manifestations of AF. Early identification of this cohort of patients may allow early initiation of anticoagulation and reduce the risk of secondary stroke. Objective: This study aims to produce a substrate-based predictive model using cardiac magnetic resonance imaging (CMR) and baseline noninvasive electrocardiographic investigations to improve the identification of patients at risk of future thromboembolism. Methods: CARM-AF is a prospective, multicenter, observational cohort study. Ninety-two patients will be recruited following an embolic stroke of unknown source (ESUS) and undergo atrial CMR followed by insertion of an implantable loop recorder (ILR) as per routine clinical care within 3 months of index stroke. Remote ILR follow-up will be used to allocate patients to a study or control group determined by the presence or absence of AF as defined by ILR monitoring. Results: Baseline data collection, noninvasive electrocardiographic data analysis, and imaging postprocessing will be performed at the time of enrollment. Primary analysis will be performed following 12 months of continuous ILR monitoring, with interim and delayed analyses performed at 6 months and 2 and 3 years, respectively. Conclusion: The CARM-AF Study will use atrial structural and electrocardiographic metrics to identify patients with AF, or at high risk of developing AF, who may benefit from early initiation of anticoagulation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA